Eintrag weiter verarbeiten
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons
Gespeichert in:
Zeitschriftentitel: | Journal of Physics: Conference Series |
---|---|
Personen und Körperschaften: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
In: | Journal of Physics: Conference Series, 1561, 2020, 1, S. 012010 |
Format: | E-Article |
Sprache: | Unbestimmt |
veröffentlicht: |
IOP Publishing
|
Schlagwörter: |
author_facet |
Frosin, C Barlini, S Poggi, G Casini, G Bini, M Stefanini, A A Valdré, S Gruyer, D Ciemala, M Maj, A Ziebliński, M Sowicki, B Mazurek, K Cieplicka-Oryńczak, N Matejska-Minda, M Bonnet, E Borderie, B Bougault, R Bruno, M Buccola, A Camaiani, A Chibhi, A Cinausero, M Cicerchia, M Dueñs, J Fabris, D Frankland, J Gramegna, F Henri, M Kordyasz, A Le Neindre, N Lombardo, I Lopez, O Mantovani, G Marchi, T Olmi, A Ottanelli, P Parlog, M Piantelli, S Pasquali, G Upadhyahya, S Verde, G Vient, E Frosin, C Barlini, S Poggi, G Casini, G Bini, M Stefanini, A A Valdré, S Gruyer, D Ciemala, M Maj, A Ziebliński, M Sowicki, B Mazurek, K Cieplicka-Oryńczak, N Matejska-Minda, M Bonnet, E Borderie, B Bougault, R Bruno, M Buccola, A Camaiani, A Chibhi, A Cinausero, M Cicerchia, M Dueñs, J Fabris, D Frankland, J Gramegna, F Henri, M Kordyasz, A Le Neindre, N Lombardo, I Lopez, O Mantovani, G Marchi, T Olmi, A Ottanelli, P Parlog, M Piantelli, S Pasquali, G Upadhyahya, S Verde, G Vient, E |
---|---|
author |
Frosin, C Barlini, S Poggi, G Casini, G Bini, M Stefanini, A A Valdré, S Gruyer, D Ciemala, M Maj, A Ziebliński, M Sowicki, B Mazurek, K Cieplicka-Oryńczak, N Matejska-Minda, M Bonnet, E Borderie, B Bougault, R Bruno, M Buccola, A Camaiani, A Chibhi, A Cinausero, M Cicerchia, M Dueñs, J Fabris, D Frankland, J Gramegna, F Henri, M Kordyasz, A Le Neindre, N Lombardo, I Lopez, O Mantovani, G Marchi, T Olmi, A Ottanelli, P Parlog, M Piantelli, S Pasquali, G Upadhyahya, S Verde, G Vient, E |
spellingShingle |
Frosin, C Barlini, S Poggi, G Casini, G Bini, M Stefanini, A A Valdré, S Gruyer, D Ciemala, M Maj, A Ziebliński, M Sowicki, B Mazurek, K Cieplicka-Oryńczak, N Matejska-Minda, M Bonnet, E Borderie, B Bougault, R Bruno, M Buccola, A Camaiani, A Chibhi, A Cinausero, M Cicerchia, M Dueñs, J Fabris, D Frankland, J Gramegna, F Henri, M Kordyasz, A Le Neindre, N Lombardo, I Lopez, O Mantovani, G Marchi, T Olmi, A Ottanelli, P Parlog, M Piantelli, S Pasquali, G Upadhyahya, S Verde, G Vient, E Journal of Physics: Conference Series Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons General Physics and Astronomy |
author_sort |
frosin, c |
spelling |
Frosin, C Barlini, S Poggi, G Casini, G Bini, M Stefanini, A A Valdré, S Gruyer, D Ciemala, M Maj, A Ziebliński, M Sowicki, B Mazurek, K Cieplicka-Oryńczak, N Matejska-Minda, M Bonnet, E Borderie, B Bougault, R Bruno, M Buccola, A Camaiani, A Chibhi, A Cinausero, M Cicerchia, M Dueñs, J Fabris, D Frankland, J Gramegna, F Henri, M Kordyasz, A Le Neindre, N Lombardo, I Lopez, O Mantovani, G Marchi, T Olmi, A Ottanelli, P Parlog, M Piantelli, S Pasquali, G Upadhyahya, S Verde, G Vient, E 1742-6588 1742-6596 IOP Publishing General Physics and Astronomy http://dx.doi.org/10.1088/1742-6596/1561/1/012010 <jats:title>Abstract</jats:title> <jats:p>Proton energy calibration and identification efficiency of few Thallium activated Cesium Iodide (CsI(Tl)) crystals of the FAZIA detection system, have been studied in the range 59-180 MeV by using the proton beam delivered by the cyclotron of the CCB (Cyclotron Center Bronowice) facility. We observe that the light output versus energy is linear in the lower investigated energy range while showing a deviation from linearity above 140 MeV. The effects of proton induced nuclear reactions and multiple scattering causing incomplete energy deposition (IED) events have been identified and estimated via Pulse Shape Analysis in CsI(Tl) crystals. The measured experimental efficiency for proton identification in the examined energy range is then compared with GEANT4 simulations. For a centered collimated irradiation on the crystal, and at the highest measured energy, the resulting experimental efficiency value is about 70%.</jats:p> Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons Journal of Physics: Conference Series |
doi_str_mv |
10.1088/1742-6596/1561/1/012010 |
facet_avail |
Online Free |
format |
ElectronicArticle |
fullrecord |
blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTA4OC8xNzQyLTY1OTYvMTU2MS8xLzAxMjAxMA |
id |
ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTA4OC8xNzQyLTY1OTYvMTU2MS8xLzAxMjAxMA |
institution |
DE-Gla1 DE-Zi4 DE-15 DE-Pl11 DE-Rs1 DE-105 DE-14 DE-Ch1 DE-L229 DE-D275 DE-Bn3 DE-Brt1 DE-Zwi2 DE-D161 |
imprint |
IOP Publishing, 2020 |
imprint_str_mv |
IOP Publishing, 2020 |
issn |
1742-6588 1742-6596 |
issn_str_mv |
1742-6588 1742-6596 |
language |
Undetermined |
mega_collection |
IOP Publishing (CrossRef) |
match_str |
frosin2020energyresponseandidentificationefficiencyofcsitlcrystalsirradiatedwithenergeticprotons |
publishDateSort |
2020 |
publisher |
IOP Publishing |
recordtype |
ai |
record_format |
ai |
series |
Journal of Physics: Conference Series |
source_id |
49 |
title |
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_unstemmed |
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_full |
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_fullStr |
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_full_unstemmed |
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_short |
Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_sort |
energy response and identification efficiency of csi(tl) crystals irradiated with energetic protons |
topic |
General Physics and Astronomy |
url |
http://dx.doi.org/10.1088/1742-6596/1561/1/012010 |
publishDate |
2020 |
physical |
012010 |
description |
<jats:title>Abstract</jats:title>
<jats:p>Proton energy calibration and identification efficiency of few Thallium activated Cesium Iodide (CsI(Tl)) crystals of the FAZIA detection system, have been studied in the range 59-180 MeV by using the proton beam delivered by the cyclotron of the CCB (Cyclotron Center Bronowice) facility. We observe that the light output versus energy is linear in the lower investigated energy range while showing a deviation from linearity above 140 MeV. The effects of proton induced nuclear reactions and multiple scattering causing incomplete energy deposition (IED) events have been identified and estimated via Pulse Shape Analysis in CsI(Tl) crystals. The measured experimental efficiency for proton identification in the examined energy range is then compared with GEANT4 simulations. For a centered collimated irradiation on the crystal, and at the highest measured energy, the resulting experimental efficiency value is about 70%.</jats:p> |
container_issue |
1 |
container_start_page |
0 |
container_title |
Journal of Physics: Conference Series |
container_volume |
1561 |
format_de105 |
Article, E-Article |
format_de14 |
Article, E-Article |
format_de15 |
Article, E-Article |
format_de520 |
Article, E-Article |
format_de540 |
Article, E-Article |
format_dech1 |
Article, E-Article |
format_ded117 |
Article, E-Article |
format_degla1 |
E-Article |
format_del152 |
Buch |
format_del189 |
Article, E-Article |
format_dezi4 |
Article |
format_dezwi2 |
Article, E-Article |
format_finc |
Article, E-Article |
format_nrw |
Article, E-Article |
_version_ |
1792324569973915655 |
geogr_code |
not assigned |
last_indexed |
2024-03-01T11:51:48.263Z |
geogr_code_person |
not assigned |
openURL |
url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Energy+response+and+identification+efficiency+of+CsI%28Tl%29+crystals+irradiated+with+energetic+protons&rft.date=2020-06-01&genre=article&issn=1742-6596&volume=1561&issue=1&pages=012010&jtitle=Journal+of+Physics%3A+Conference+Series&atitle=Energy+response+and+identification+efficiency+of+CsI%28Tl%29+crystals+irradiated+with+energetic+protons&aulast=Vient&aufirst=E&rft_id=info%3Adoi%2F10.1088%2F1742-6596%2F1561%2F1%2F012010&rft.language%5B0%5D=und |
SOLR | |
_version_ | 1792324569973915655 |
author | Frosin, C, Barlini, S, Poggi, G, Casini, G, Bini, M, Stefanini, A A, Valdré, S, Gruyer, D, Ciemala, M, Maj, A, Ziebliński, M, Sowicki, B, Mazurek, K, Cieplicka-Oryńczak, N, Matejska-Minda, M, Bonnet, E, Borderie, B, Bougault, R, Bruno, M, Buccola, A, Camaiani, A, Chibhi, A, Cinausero, M, Cicerchia, M, Dueñs, J, Fabris, D, Frankland, J, Gramegna, F, Henri, M, Kordyasz, A, Le Neindre, N, Lombardo, I, Lopez, O, Mantovani, G, Marchi, T, Olmi, A, Ottanelli, P, Parlog, M, Piantelli, S, Pasquali, G, Upadhyahya, S, Verde, G, Vient, E |
author_facet | Frosin, C, Barlini, S, Poggi, G, Casini, G, Bini, M, Stefanini, A A, Valdré, S, Gruyer, D, Ciemala, M, Maj, A, Ziebliński, M, Sowicki, B, Mazurek, K, Cieplicka-Oryńczak, N, Matejska-Minda, M, Bonnet, E, Borderie, B, Bougault, R, Bruno, M, Buccola, A, Camaiani, A, Chibhi, A, Cinausero, M, Cicerchia, M, Dueñs, J, Fabris, D, Frankland, J, Gramegna, F, Henri, M, Kordyasz, A, Le Neindre, N, Lombardo, I, Lopez, O, Mantovani, G, Marchi, T, Olmi, A, Ottanelli, P, Parlog, M, Piantelli, S, Pasquali, G, Upadhyahya, S, Verde, G, Vient, E, Frosin, C, Barlini, S, Poggi, G, Casini, G, Bini, M, Stefanini, A A, Valdré, S, Gruyer, D, Ciemala, M, Maj, A, Ziebliński, M, Sowicki, B, Mazurek, K, Cieplicka-Oryńczak, N, Matejska-Minda, M, Bonnet, E, Borderie, B, Bougault, R, Bruno, M, Buccola, A, Camaiani, A, Chibhi, A, Cinausero, M, Cicerchia, M, Dueñs, J, Fabris, D, Frankland, J, Gramegna, F, Henri, M, Kordyasz, A, Le Neindre, N, Lombardo, I, Lopez, O, Mantovani, G, Marchi, T, Olmi, A, Ottanelli, P, Parlog, M, Piantelli, S, Pasquali, G, Upadhyahya, S, Verde, G, Vient, E |
author_sort | frosin, c |
container_issue | 1 |
container_start_page | 0 |
container_title | Journal of Physics: Conference Series |
container_volume | 1561 |
description | <jats:title>Abstract</jats:title> <jats:p>Proton energy calibration and identification efficiency of few Thallium activated Cesium Iodide (CsI(Tl)) crystals of the FAZIA detection system, have been studied in the range 59-180 MeV by using the proton beam delivered by the cyclotron of the CCB (Cyclotron Center Bronowice) facility. We observe that the light output versus energy is linear in the lower investigated energy range while showing a deviation from linearity above 140 MeV. The effects of proton induced nuclear reactions and multiple scattering causing incomplete energy deposition (IED) events have been identified and estimated via Pulse Shape Analysis in CsI(Tl) crystals. The measured experimental efficiency for proton identification in the examined energy range is then compared with GEANT4 simulations. For a centered collimated irradiation on the crystal, and at the highest measured energy, the resulting experimental efficiency value is about 70%.</jats:p> |
doi_str_mv | 10.1088/1742-6596/1561/1/012010 |
facet_avail | Online, Free |
format | ElectronicArticle |
format_de105 | Article, E-Article |
format_de14 | Article, E-Article |
format_de15 | Article, E-Article |
format_de520 | Article, E-Article |
format_de540 | Article, E-Article |
format_dech1 | Article, E-Article |
format_ded117 | Article, E-Article |
format_degla1 | E-Article |
format_del152 | Buch |
format_del189 | Article, E-Article |
format_dezi4 | Article |
format_dezwi2 | Article, E-Article |
format_finc | Article, E-Article |
format_nrw | Article, E-Article |
geogr_code | not assigned |
geogr_code_person | not assigned |
id | ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTA4OC8xNzQyLTY1OTYvMTU2MS8xLzAxMjAxMA |
imprint | IOP Publishing, 2020 |
imprint_str_mv | IOP Publishing, 2020 |
institution | DE-Gla1, DE-Zi4, DE-15, DE-Pl11, DE-Rs1, DE-105, DE-14, DE-Ch1, DE-L229, DE-D275, DE-Bn3, DE-Brt1, DE-Zwi2, DE-D161 |
issn | 1742-6588, 1742-6596 |
issn_str_mv | 1742-6588, 1742-6596 |
language | Undetermined |
last_indexed | 2024-03-01T11:51:48.263Z |
match_str | frosin2020energyresponseandidentificationefficiencyofcsitlcrystalsirradiatedwithenergeticprotons |
mega_collection | IOP Publishing (CrossRef) |
physical | 012010 |
publishDate | 2020 |
publishDateSort | 2020 |
publisher | IOP Publishing |
record_format | ai |
recordtype | ai |
series | Journal of Physics: Conference Series |
source_id | 49 |
spelling | Frosin, C Barlini, S Poggi, G Casini, G Bini, M Stefanini, A A Valdré, S Gruyer, D Ciemala, M Maj, A Ziebliński, M Sowicki, B Mazurek, K Cieplicka-Oryńczak, N Matejska-Minda, M Bonnet, E Borderie, B Bougault, R Bruno, M Buccola, A Camaiani, A Chibhi, A Cinausero, M Cicerchia, M Dueñs, J Fabris, D Frankland, J Gramegna, F Henri, M Kordyasz, A Le Neindre, N Lombardo, I Lopez, O Mantovani, G Marchi, T Olmi, A Ottanelli, P Parlog, M Piantelli, S Pasquali, G Upadhyahya, S Verde, G Vient, E 1742-6588 1742-6596 IOP Publishing General Physics and Astronomy http://dx.doi.org/10.1088/1742-6596/1561/1/012010 <jats:title>Abstract</jats:title> <jats:p>Proton energy calibration and identification efficiency of few Thallium activated Cesium Iodide (CsI(Tl)) crystals of the FAZIA detection system, have been studied in the range 59-180 MeV by using the proton beam delivered by the cyclotron of the CCB (Cyclotron Center Bronowice) facility. We observe that the light output versus energy is linear in the lower investigated energy range while showing a deviation from linearity above 140 MeV. The effects of proton induced nuclear reactions and multiple scattering causing incomplete energy deposition (IED) events have been identified and estimated via Pulse Shape Analysis in CsI(Tl) crystals. The measured experimental efficiency for proton identification in the examined energy range is then compared with GEANT4 simulations. For a centered collimated irradiation on the crystal, and at the highest measured energy, the resulting experimental efficiency value is about 70%.</jats:p> Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons Journal of Physics: Conference Series |
spellingShingle | Frosin, C, Barlini, S, Poggi, G, Casini, G, Bini, M, Stefanini, A A, Valdré, S, Gruyer, D, Ciemala, M, Maj, A, Ziebliński, M, Sowicki, B, Mazurek, K, Cieplicka-Oryńczak, N, Matejska-Minda, M, Bonnet, E, Borderie, B, Bougault, R, Bruno, M, Buccola, A, Camaiani, A, Chibhi, A, Cinausero, M, Cicerchia, M, Dueñs, J, Fabris, D, Frankland, J, Gramegna, F, Henri, M, Kordyasz, A, Le Neindre, N, Lombardo, I, Lopez, O, Mantovani, G, Marchi, T, Olmi, A, Ottanelli, P, Parlog, M, Piantelli, S, Pasquali, G, Upadhyahya, S, Verde, G, Vient, E, Journal of Physics: Conference Series, Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons, General Physics and Astronomy |
title | Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_full | Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_fullStr | Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_full_unstemmed | Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_short | Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
title_sort | energy response and identification efficiency of csi(tl) crystals irradiated with energetic protons |
title_unstemmed | Energy response and identification efficiency of CsI(Tl) crystals irradiated with energetic protons |
topic | General Physics and Astronomy |
url | http://dx.doi.org/10.1088/1742-6596/1561/1/012010 |