Eintrag weiter verarbeiten

Failure mechanism of coated biomaterials under high impact-sliding contact stresses

Gespeichert in:

Personen und Körperschaften: Chen, Ying (VerfasserIn)
Titel: Failure mechanism of coated biomaterials under high impact-sliding contact stresses
Hochschulschriftenvermerk: Dissertation, University of Windsor, 2014
Format: E-Book
Sprache: Englisch
veröffentlicht:
[Erscheinungsort nicht ermittelbar] University of Windsor 2014
Quelle: Verbunddaten SWB
Lizenzfreie Online-Ressourcen
LEADER 03247nam a22003732 4500
001 0-180284256X
003 DE-627
005 20220512014234.0
007 cr uuu---uuuuu
008 220512s2014 xx |||||o 00| ||eng c
035 |a (DE-627)180284256X 
035 |a (DE-599)KXP180284256X 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
082 0 4 |a 620 
100 1 |a Chen, Ying  |e VerfasserIn  |4 aut 
245 1 0 |a Failure mechanism of coated biomaterials under high impact-sliding contact stresses 
264 1 |a [Erscheinungsort nicht ermittelbar]  |b University of Windsor  |c 2014 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
502 |b Dissertation  |c University of Windsor  |d 2014 
520 |a This study uses a newly developed testing method-- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support to coating better and a ductile and adhesive interface layer can delay the cracked coating from peeled-off. 
856 4 0 |u https://scholar.uwindsor.ca/etd/5099  |x Verlag  |z kostenfrei 
912 |a GBV-BASE-ODISS 
951 |a BO 
856 4 0 |u https://scholar.uwindsor.ca/etd/5099  |9 LFER 
852 |a LFER  |z 2022-06-15T11:28:29Z 
970 |c OD 
971 |c EBOOK 
972 |c EBOOK 
973 |c EB 
935 |a lfer 
980 |a 180284256X  |b 0  |k 180284256X  |c lfer 
openURL url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Failure+mechanism+of+coated+biomaterials+under+high+impact-sliding+contact+stresses&rft.date=2014&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.creator=Chen%2C+Ying&rft.pub=University+of+Windsor&rft.format=eBook&rft.language=English
SOLR
_version_ 1750442810369114112
access_facet Electronic Resources
author Chen, Ying
author_facet Chen, Ying
author_role aut
author_sort Chen, Ying
author_variant y c yc
callnumber-sort
collection GBV-BASE-ODISS, lfer
contents This study uses a newly developed testing method-- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support to coating better and a ductile and adhesive interface layer can delay the cracked coating from peeled-off.
ctrlnum (DE-627)180284256X, (DE-599)KXP180284256X
dewey-full 620
dewey-hundreds 600 - Technology
dewey-ones 620 - Engineering & allied operations
dewey-raw 620
dewey-search 620
dewey-sort 3620
dewey-tens 620 - Engineering
facet_912a GBV-BASE-ODISS
facet_avail Online, Free
finc_class_facet Technik
fincclass_txtF_mv technology, engineering-process
format eBook
format_access_txtF_mv Book, E-Book
format_de105 Ebook
format_de14 Book, E-Book
format_de15 Book, E-Book
format_del152 Buch
format_detail_txtF_mv text-online-monograph-independent
format_dezi4 e-Book
format_finc Book, E-Book
format_legacy ElectronicBook
format_legacy_nrw Book, E-Book
format_nrw Book, E-Book
format_strict_txtF_mv E-Book
geogr_code not assigned
geogr_code_person not assigned
id 0-180284256X
illustrated Not Illustrated
imprint [Erscheinungsort nicht ermittelbar], University of Windsor, 2014
imprint_str_mv [Erscheinungsort nicht ermittelbar]: University of Windsor, 2014
institution DE-D117, DE-105, LFER, DE-Ch1, DE-15, DE-14, DE-Zwi2
is_hierarchy_id
is_hierarchy_title
isil_str_mv LFER
kxp_id_str 180284256X
language English
last_indexed 2022-11-25T04:59:07.928Z
match_str chen2014failuremechanismofcoatedbiomaterialsunderhighimpactslidingcontactstresses
mega_collection Verbunddaten SWB, Lizenzfreie Online-Ressourcen
misc_de105 EBOOK
publishDate 2014
publishDateSort 2014
publishPlace [Erscheinungsort nicht ermittelbar]
publisher University of Windsor
record_format marcfinc
record_id 180284256X
recordtype marcfinc
rvk_facet No subject assigned
source_id 0
spelling Chen, Ying VerfasserIn aut, Failure mechanism of coated biomaterials under high impact-sliding contact stresses, [Erscheinungsort nicht ermittelbar] University of Windsor 2014, Text txt rdacontent, Computermedien c rdamedia, Online-Ressource cr rdacarrier, Dissertation University of Windsor 2014, This study uses a newly developed testing method-- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support to coating better and a ductile and adhesive interface layer can delay the cracked coating from peeled-off., https://scholar.uwindsor.ca/etd/5099 Verlag kostenfrei, https://scholar.uwindsor.ca/etd/5099 LFER, LFER 2022-06-15T11:28:29Z
spellingShingle Chen, Ying, Failure mechanism of coated biomaterials under high impact-sliding contact stresses, This study uses a newly developed testing method-- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support to coating better and a ductile and adhesive interface layer can delay the cracked coating from peeled-off.
title Failure mechanism of coated biomaterials under high impact-sliding contact stresses
title_auth Failure mechanism of coated biomaterials under high impact-sliding contact stresses
title_full Failure mechanism of coated biomaterials under high impact-sliding contact stresses
title_fullStr Failure mechanism of coated biomaterials under high impact-sliding contact stresses
title_full_unstemmed Failure mechanism of coated biomaterials under high impact-sliding contact stresses
title_short Failure mechanism of coated biomaterials under high impact-sliding contact stresses
title_sort failure mechanism of coated biomaterials under high impact sliding contact stresses
url https://scholar.uwindsor.ca/etd/5099